One-click IO diagnosis
One-click IO Diagnosis helps you resolve common IO issues such as high IO latency, IO burst, and IO wait. It identifies the issue type, analyzes the data using specialized sub-tools, and provides diagnostic conclusions and recommendations.
Limitations
-
Region restrictions
-
Operating system restrictions
Architecture
Operating system
x86 architecture
-
Rocky Linux 9.5
-
Rocky Linux 9.1
-
Ubuntu 20.04
-
Alibaba Cloud Linux 3 Container Optimized Edition
-
Rocky Linux 8.8
-
Ubuntu 22.04
-
Alibaba Cloud Linux 3 Pro
-
Alibaba Cloud Linux 2/3
-
CentOS 7.6 or later, or CentOS 8
-
Anolis OS 7/8
-
Ubuntu 24.04
ARM architecture
-
Alibaba Cloud Linux 3 Pro
-
Alibaba Cloud Linux 3
-
Use cases
-
Troubleshoot high IO latency to determine whether the bottleneck is in the operating system (OS) or a backend service.
-
Identify the specific process causing abnormal IO traffic.
-
Investigate the root cause and problematic IO path of a spike in the IO wait metric.
Prerequisites
-
If you use a RAM user, make sure that the Alibaba Cloud account (primary account) has granted the RAM user the
AliyunECSReadOnlyAccessandAliyunSysomFullAccesssystem policies. -
The console permissions are activated.
The first time you log on to the Operating System Console, click Activate Service to activate the console service.
Procedure
-
Go to Operating System Console.
-
In the left-side navigation pane, click System Diagnosis.
-
In the upper part of the left-side navigation pane, select the region in which the target instance resides.

-
From the Diagnosis Type list, select Storage Diagnosis. Then, in the Diagnosis Item section, select One-click IO Diagnosis. Configure the parameters and click Run Diagnosis.
NoteIf SysOM is not installed, the system automatically installs SysOM on the target ECS instance and then starts the diagnosis after you click Run Diagnosis.
The following table describes the parameters.
Parameter
Description
Required
Instance ID
The ID of the target ECS instance.
Yes
Diagnosis Duration
The diagnosis duration. A minimum of 30 seconds is recommended.
No
-
In the Diagnosis Records section, click View Report.
Diagnostic report
-
Basic Information
The Basic Information section summarizes the diagnosis with key details, including the instance ID (which serves as the resource ID), diagnosis item, diagnostic report ID, and diagnosis start time.
-
Diagnosis conclusion
If an IO anomaly is detected, this section displays the identified issue and its root cause analysis.
-
Recommendations
This section recommends actions based on the diagnosis results.
-
Diagnosis details
-
Diagnosis summary
If an IO anomaly is found, this section shows the number of anomaly types detected.
-
Diagnosis results
This section displays the IO anomalies that occurred during the diagnosis period.
-
Device Name: The name of the detected disk or partition. -
Abnormal Point: The specific symptom of the anomaly. -
Abnormal Type: The type of the anomaly. -
Suggestion: Recommended optimizations. -
Cause: The root cause of the anomaly.
-
-