CheckMetaPartition

Updated at:

Checks whether a partition in a MaxCompute metatable exists.

Try it now

Try this API in OpenAPI Explorer, no manual signing needed. Successful calls auto-generate SDK code matching your parameters. Download it with built-in credential security for local usage.

Test

RAM authorization

No authorization for this operation. If you encounter issues with this operation, contact technical support.

Request parameters

Parameter

Type

Required

Description

Example

TableGuid

string

No

The GUID of the MaxCompute metatable.

odps.engine_name.table_name

Partition

string

Yes

The name of the partition in the MaxCompute metatable.

ds=202005

ClusterId

string

No

This parameter is deprecated.

abc

DatabaseName

string

No

The name of the metadatabase.

abc

TableName

string

No

The name of the metatable.

abc

DataSourceType

string

No

The type of the data source. Set the value to odps.

odps

Response elements

Element

Type

Description

Example

object

The response parameters.

HttpStatusCode

integer

The HTTP status code.

200

Data

boolean

Indicates whether the partition in the MaxCompute metatable exists. Valid values:

  • true

  • false

true

RequestId

string

The request ID.

0bc1ec92159376

ErrorMessage

string

The error message.

The connection does not exist.

ErrorCode

string

The error code.

Invalid.Tenant.ConnectionNotExists

Success

boolean

Indicates whether the request was successful.

true

Examples

Success response

JSON format

{
  "HttpStatusCode": 200,
  "Data": true,
  "RequestId": "0bc1ec92159376",
  "ErrorMessage": "The connection does not exist.",
  "ErrorCode": "Invalid.Tenant.ConnectionNotExists",
  "Success": true
}

Error codes

HTTP status code

Error code

Error message

Description

400 Invalid.Meta.TableNotExist The table does not exist. The table does not exist.
400 InvalidParameter.Meta.CommonError The specified parameter is invalid. The request parameter is invalid.
400 InvalidParameter.Meta.Illegal The app guid parameter is invalid. The app guid parameter is invalid.
400 InvalidParameter.Meta.NotExist The object does not exist.
400 InternalError.UserId.Missing An internal system error occurred. Try again later.
400 InternalError.Meta.NoCalcEngine An error occurred while retrieving the compute engine based on the MaxCompute project. Incorrect project entered by user
500 InternalError.System An internal system error occurred. Try again later.
500 InternalError.Meta.TenantTimeOut Failed to connect to the interface network. Failed to connect to the interface network.
500 InternalError.Meta.Unknown An unknown error occurred while processing your request. An unknown error occurred while processing your request.
403 Forbidden.Meta.NoTenant The user is not the owner of any tenants. The user is not the owner of any tenants.
403 Forbidden.Access Access is forbidden. Please first activate DataWorks Enterprise Edition or Flagship Edition. No permission, please authorize
429 Throttling.Api The request for this resource has exceeded your available limit.
429 Throttling.Api.Risk The request for this resource has exceeded your daily available limit.
429 Throttling.System The DataWorks system is busy. Try again later.
429 Throttling.User Your request is too frequent. Try again later.

See Error Codes for a complete list.

Release notes

See Release Notes for a complete list.