Cloud disk performance
Edge Node Service (ENS) offers all-flash cloud disks and ultra cloud disks with different performance characteristics. This topic describes the key performance metrics, performance specifications, and calculation formulas for each cloud disk type to help you choose the right disk for your workload.
Performance metrics
Cloud disk performance is primarily measured by IOPS, throughput, and access latency. The actual performance of a cloud disk depends on its type and capacity.
I/O size
I/O size is the amount of data in each read or write operation. For example, a typical I/O size is 4 KiB. I/O size determines which performance metric matters most for your application, based on the following relationship:
IOPS × I/O size = Throughput
If your application uses small, random I/O operations, focus on IOPS. If your application uses large, sequential I/O operations, focus on throughput.
IOPS
Input/Output Operations per Second (IOPS) measures the number of read and write operations a cloud disk can handle per second. IOPS is the key metric for latency-sensitive workloads with small, random I/O patterns, such as databases.
Throughput
Throughput measures the amount of data that can be transferred per second, expressed in MB/s. Throughput is the key metric for workloads with large, sequential I/O patterns, such as big data analytics and log processing.
Access latency
Access latency is the time required for a cloud disk to process a single I/O operation, measured in milliseconds (ms) or microseconds (μs). High latency can degrade application performance or cause errors. If your application is sensitive to latency, such as a relational database, use all-flash cloud disks for optimal performance.
How capacity affects performance
Cloud disk capacity is measured in binary units (1 GiB = 1,024 MiB). Although capacity is not a performance metric, it directly affects the achievable IOPS and throughput of a cloud disk.
For the same disk type, each GiB of capacity provides the same per-unit I/O performance. The total performance scales linearly with capacity until it reaches the per-disk maximum for that disk type. A larger disk delivers higher IOPS and throughput.
Performance specifications
The following table compares the performance specifications of each cloud disk type.
-
Starting July 1, 2026, newly purchased cloud disks will be provisioned with the baseline performance specifications listed in the following table.
-
Ultra cloud disks are a previous-generation product and are being phased out at some edge nodes.
-
Due to architecture differences, ultra cloud disks at a small number of edge nodes may not conform to the baseline performance specifications.
|
Metric |
All-flash cloud disk |
Ultra cloud disk |
|
Per-disk capacity range (GiB) |
20–32,768 |
20–32,768 |
|
Maximum IOPS |
20,000 |
1,000 |
|
Maximum throughput (MB/s) |
180 |
50 |
|
IOPS calculation formula |
|
|
|
Throughput calculation formula (MB/s) |
|
|
|
Data reliability |
99.9999% |
99.9999% |
|
Average single-path random write latency (ms), block size = 4 KiB |
1–3 |
5–10 |
Baseline performance
Baseline performance refers to the maximum IOPS and throughput provisioned when a cloud disk is created. These values scale linearly with disk capacity. Different disk types have different maximum baseline performance values.
Performance calculation formulas
Each disk type uses a formula based on capacity to determine the IOPS and throughput. In each formula, the performance starts at a base value, increases by a fixed amount per GiB, and is capped at the per-disk maximum.
All-flash cloud disk
-
Maximum IOPS: Starts at 200, increases by 10 per GiB, capped at 20,000.
-
Maximum throughput: Starts at 20 MB/s, increases by 0.15 MB/s per GiB, capped at 180 MB/s.
Ultra cloud disk
-
Maximum IOPS: Starts at 25, increases by 0.5 per GiB, capped at 1,000.
-
Maximum throughput: Starts at 5 MB/s, increases by 0.02 MB/s per GiB, capped at 50 MB/s.
Example
If you create a 500 GiB all-flash cloud disk:
-
IOPS = min{200 + 10 × 500, 20,000} = min{5,200, 20,000} = 5,200
-
Throughput = min{20 + 0.15 × 500, 180} = min{95, 180} = 95 MB/s
Disk selection guide
Use the following table to select the right cloud disk type based on your workload requirements.
|
Scenario |
Recommended disk type |
Reason |
|
Relational databases (MySQL, PostgreSQL) |
All-flash cloud disk |
Low latency (1–3 ms) and high IOPS for random read/write operations. |
|
Big data analytics and log processing |
All-flash cloud disk |
High throughput (up to 180 MB/s) for large sequential I/O operations. |
|
Small websites and development environments |
Ultra cloud disk (where available) |
Cost-effective option for workloads with moderate I/O requirements. Ultra cloud disks are being phased out at some edge nodes. Use all-flash cloud disks where ultra cloud disks are unavailable. |
Local disk performance
Local disks are physically attached to the host machine and provide high-performance temporary storage. Unlike cloud disks, local disks cannot be created independently — they are allocated together with the instance.
-
Data reliability of local disks depends on the physical host. A single point of failure on the host machine may affect all instances on the same host.
-
Storing data on local disks carries a risk of data loss. Do not store business-critical data that requires long-term persistence on local disks.
-
ENS does not provide performance specifications for local disks at this time.